2 Ton 15.2 SEER2 Goodman Heat Pump Split System GLZS4BA2410+AMST24BU1300 R-32
Standard Features
- High-efficiency compressor
- SmartShift® technology to ensure quiet reliable defrost
- Enhanced aluminum fin coil- 5 mm diameter on 1.5T-3.5 Ton
- Enhanced aluminum fin coil with 7mm diameter copper tubes in 4.0- to 5.0-ton
- Single-speed PSC condenser fan motor
- Factory-installed bi-flow liquid-line filter drier
- Factory-installed suction-line accumulator
- Factory-installed compressor crankcase heater
- Factory-installed high-capacity muffler
- High- and low-pressure switches
- Service valves with sweat connections and easy access to gauge ports
- Fully charged for 15’ of tubing length
- Fully enclosed contactor with lug connection
- Ground lug connection
- Capacitors with extended life
- AHRI Certified; ETL Listed
Cabinet Features
- Removable grille-style top design compliant with UL 60335-2-40
- Steel louver coil guard
- Heavy-gauge galvanized-steel cabinet
- Attractive Architectural Gray powder-paint finish with 500-hour salt-spray approval
- Top and side maintenance access
- When properly anchored, meets the 2023 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)
UNIT NOT THE INDOOR COIL.
¹ Tested and rated in accordance with ARI Standard 210/240
2 Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes
3 Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.
Notes
• Always check the S&R plate for electrical data on the unit being installed.
• Installer will need to supply ⅞” to 1⅛” adapters for suction line connections.
• Unit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure.
• Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR
GLZS4BA2410
GLZS4BA2410 | |
Nominal Capacities | |
Cooling (BTU/h) | 24,000 |
Heating (BTU/h) | 24,000 |
Decibels | 74 |
Compressor | |
RLA | 8.2 |
LRA | 41.2 |
Stage | Single |
Type | Rotary |
Condenser Fan Motor | |
Motor Type | PSC |
Horsepower | 1/6 |
FLA | 0.95 |
Refrigeration System | |
Refrigerant Line Size¹ | |
Liquid Line Size (“O.D.) | ⅜" |
Suction Line Size (“O.D.) | ¾" |
Refrigerant Connection Size | |
Liquid Valve Size (“O.D.) | ⅜" |
Suction Valve Size (“O.D.) | ¾" |
Valve Connection Type | Sweat |
Refrigerant Charge (oz.) | 70 |
Electrical Data | |
Volts/Phase (60 Hz) | 208/230 |
Minimum Circuit Ampacity 2 | 11.2 |
Max. Overcurrent Protection 3 | 15 |
Min / Max Volts | 197/253 |
Electrical Conduit Size | 1/2" or 3/4" |
Unit Weights | |
Equipment Weight (lbs.) | 150 |
Ship Weight (lbs) | 165 |
Product Features
- Internal factory-installed thermal expansion valves for cooling and heat pump applications
- Direct drive, multi-speed ECM blower motor
- All-aluminum evaporator coil
- Coil mounting track for quick repositioning
- Optimized for use with R-32 refrigerant
- Cabinet air leakage less than 2.0% at 1.0 inch H₂O when tested in accordance with ASHRAE standard 193
- Cabinet air leakage less than 1.4% at 0.5 inch H₂O when tested in accordance with ASHRAE standard 193
- AHRI certified; ETL listed
- UL 60335 2-40 Compliant
- Factory installed R32 sensor designed for lifespan of coil
- Rigid SmartFrame™ cabinet
- Horizontal or vertical configuration capabilities
- 21″ depth for easier attic access
- DecaBDE-free thermoplastic drain pan with secondary drain connections
- Screw-less sides and back helps to reduce condensation when installed in humid locations
- Foil-faced insulation covers the internal casing to reduce cabinet condensation
- Galvanized, leather grain-embossed finish
- Glue-less cabinet insulation retention
- Tool-less filter access
- Field Installed 3 kW – 25 kW electric heater kits available
AMST24BU1300
Nominal Ratings | |
Cooling (Btu/h) | 24,000 |
Nominal Tons | 1.5 Ton |
Blower | |
Diameter | 10" |
Width | 6" |
Coil Connections | |
Liquid | ⅜" |
Suction | ¾" |
Coil Drain Connect (FPT) | ¾" |
Electrical Data | |
Voltage | 208/240 -1 |
Minimum Circuit Ampacity | 5.8 |
Max. Overcurrent Device (Amps) | 15 |
Min. / Max VAC | 197 / 253 |
Blower Motor | |
Full Load Amps (FLA) | 4.6 |
Horsepower (HP) | ¾ |
Ship Weight (Lbs.) | 112 |
Prop 65 Warning:
Warning: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. For more information: www.P65Warnings.ca.gov
$3,444.00
-