3.5 Ton 14.5 SEER2 Goodman AC Split System GSXN404210+AMST42CU1400 (Not a Heat Pump)

Storewide Sale 

Add To Cart To See Savings

3.5 Ton 14.5 SEER2 Goodman AC Split System GSXN404210+AMST42CU1400 (Not a Heat Pump)

Standard Features
• Energy-Efficient Compressor
• Copper tube/ enhanced aluminum fin coil-5mm diameter on 1.5-4.0T
• Factory-installed filter drier
• Fully charged for 15’ of tubing length
• Service valves with sweat connections and easy-to-access gauge ports
• Contactor with lug connection
• Ground lug connection
• AHRI Certified
• ETL Listed

Cabinet Features
• Removable grille-style top design compliant with UL 60335-2-40
• Heavy-gauge galvanized-steel cabinet
• Attractive Architectural Gray powder-paint finish with 500-hour salt-spray approval
• Steel louver coil guard
• Single-panel access to controls with space provided for field-installed accessories
• When properly anchored, meets the 2020 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)

GSXN404210

GSXN404210
Capacities
Nominal Cooling (BTU/h) 42,000
Decibels (dBA) 71
Compressor
RLA 17.7
LRA 110.2
Stage Single
Type Scroll
Condenser Fan Motor
Motor Type PSC
Horsepower 1/6
FLA 0.97
Refrigeration System
Refrigerant Line Size
Liquid Line Size (“O.D.) ⅜”
Suction Line Size (“O.D.) ⅞”
Refrigerant Connection Size
Liquid Valve Size (“O.D.) ⅜”
Suction Valve Size ⅞”
Valve Type Sweat
Refrigerant Charge 107
Electrical Data
Voltage-Phase (60 Hz) 208/230-1
Minimum Circuit Ampacity 23.1
Max. Overcurrent Protection 40
Min / Max Volts 197/253
Electrical Conduit Size ½” or ¾”
Equipment Weight (lbs) 226
Ship Weight (lbs) 248

Product Features
• Internal factory-installed thermal expansion valves for cooling and heat pump applications
• Direct drive, multi-speed ECM blower motor
• All-aluminum evaporator coil
• Coil mounting track for quick repositioning
• Optimized for use with R-410A refrigerant
• Cabinet air leakage less than 2.0% at 1.0 inch H₂O when tested in accordance with ASHRAE standard193
• Cabinet air leakage less than 1.4% at 0.5 inch H₂O when tested in accordance with ASHRAE standard193
• AHRI certified; ETL listed
• Rigid SmartFrame™ cabinet
• Horizontal or vertical configuration capabilities
• 21” depth for easier attic access
• DecaBDE-free thermoplastic drain pan with secondary drain connections
• Screw-less sides and back helps to reduce con- densation when installed in humid locations
• Foil-faced insulation covers the internal casing to reduce cabinet condensation
• Galvanized, leather grain-embossed finish
• Glue-less cabinet insulation retention
• Tool-less filter access
• Field Installed 3 kW – 25 kW electric heater kits available

AMST42CU1400

AMST42CU1400
Nominal Ratings
Cooling (Btu/h) 42,000
Blower
Diameter 10″
Width 8″
Coil Connections
Liquid 3/8″
Suction 3/4”
Coil Drain Connect (FPT) 3/4”
Electrical Data
Voltage 208/230
Minimum Circuit Ampacity 5.9/5.9
Max. Overcurrent Device (Amps) 15/15
Minimum VAC 197
Maximum VAC 253
Blower Motor
Full Load Amps (FLA) 4.7
Horsepower (HP) ¾
Ship Weight (Lbs.) 153

AMST42CU1400 Heat Kit Specs

Heater Kit Model Circuit 1 Circuit 2 Single-Point Kit
  Heater Amps Mininum Circuit Ampacity 208/230 Max Over Current Protection 208/230 Heater Amps Mininum Circuit Ampacity 208/230 Max Over Current Protection 208/230 Mininum Circuit Ampacity 208/230 Max Over Current Protection 208/230
AMST42CU1400 0/0 5.9/5.9 15/15          
3 KW 10.8/12.5 19/21.5 20/25          
5 KW 17.3/20 28/30.9 30/35          
6 KW 21.7/25 33/37.1 35/40          
8 KW 28.9/33.3 42/47.5 45/50          
10 KW 34.7/40 49/55.9 50/60          
15 KW 40 55.9 60 20 25 25 80.9 90