Standard Features 

  • High-efficiency compressor
  • SmartShift® technology to ensure quiet reliable defrost
  • Enhanced aluminum fin coil- 5 mm diameter on 1.5T-3.5 Ton
  • Enhanced aluminum fin coil with 7mm diameter copper tubes in 4.0- to 5.0-ton
  • Single-speed PSC condenser fan motor
  • Factory-installed bi-flow liquid-line filter drier
  • Factory-installed suction-line accumulator
  • Factory-installed compressor crankcase heater
  • Factory-installed high-capacity muffler
  • High- and low-pressure switches
  • Service valves with sweat connections and easy access to gauge ports
  • Fully charged for 15’ of tubing length
  • Fully enclosed contactor with lug connection
  • Ground lug connection
  • Capacitors with extended life
  • AHRI Certified; ETL Listed

Cabinet Features

  • Removable grille-style top design compliant with UL 60335-2-40
  • Steel louver coil guard
  • Heavy-gauge galvanized-steel cabinet
  • Attractive Architectural Gray powder-paint finish with 500-hour salt-spray approval
  • Top and side maintenance access
  • When properly anchored, meets the 2023 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)

¹ Tested and rated in accordance with ARI Standard 210/240
2 Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes
3 Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.
Notes
• Always check the S&R plate for electrical data on the unit being installed.
• Installer will need to supply ⅞” to 1⅛” adapters for suction line connections.
• Unit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure.
• Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR
UNIT NOT THE INDOOR COIL.

GLZS4BA3610

Nominal Capacities
Cooling (BTU/h) 36,000
Heating (BTU/h) 36,000
Decibels 75
Compressor  
RLA 16.4
LRA 88.0
Stage Single
Type Scroll
Condenser Fan Motor  
Motor Type PSC
Horsepower 1/6
FLA 0.97
Refrigeration System  
Refrigerant Line Size¹  
Liquid Line Size (“O.D.) ⅜"
Suction Line Size (“O.D.) ⅞"
Refrigerant Connection Size  
Liquid Valve Size (“O.D.) ⅜"
Suction Valve Size (“O.D.) ⅞"
Valve Connection Type Sweat
Refrigerant Charge (oz.) 83
Electrical Data  
Volts/Phase (60 Hz) 208/230
Minimum Circuit Ampacity 2 21.5
Max. Overcurrent Protection 3 35
Min / Max Volts 197/253
Electrical Conduit Size 1/2" or 3/4"
Unit Weights  
Equipment Weight (lbs.) 196

Prop 65 Warning:

Warning: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. For more information: www.P65Warnings.ca.gov