Standard Features
• Energy-efficient compressor
• Single-speed condenser fan motor
• Factory-installed filter drier
• Copper tube/aluminum fin coil
• Service valves with sweat connections and easy-access gauge ports
• Contactor with lug connection
• Ground lug connection
• AHRI Certified; ETL Listed
Cabinet Features
• Heavy-gauge galvanized-steel cabinet with a louvered sound control top
• Attractive Architectural Gray powder-paint finish with 500-hour salt-spray approval
• Steel louver coil guard
• Top and side maintenance access
• Single-panel access to controls with space provided for field-installed accessories
• When properly anchored, meets the 2010 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)
GSX140361 | |
Capacities | |
Nom Cool (BTU/h) | 36,000 |
SEER/EER | 14 / 12 |
Decibels | 73 |
Compressor | |
RLA | 14.1 |
LRA | 77 |
Condenser Fan Motor | |
Hp | 1/6 |
FLA | 0.95 |
Refrigeration System | |
Refrigerant Line Size ¹ | |
Liquid Line Size (“O.D.) | ⅜” |
Suction Line Size (“O.D.) | ⅞” |
Refrigerant Connection Size | |
Liquid Valve Size (“O.D.) | ⅜” |
Suction Valve Size (“O.D.) ² ³ | ¾” |
Valve Type | Sweat |
Charge | 81 |
Included piston: | 0.068 |
Electrical Data | |
Voltage-Phase (60 Hz) | 208/230-1 |
Minimum Circuit Ampacity ⁴ | 18.6 |
Max. Overcurrent Protection ⁵ | 30 amps |
Min/Max Volts | 197/253 |
Conduit | ½” or ¾” |
Equipment Weight | 162 |
Shipping Weight | 180 |
Product Features
• Check flowrator for cooling and heat pump applications
• Direct drive, multi-speed PSC blower motor
• All-aluminum evaporator coil
• Coil mounting track for quick repositioning
• Cabinet air leakage less than 2.0% at 1.0 inch H₂O when tested in accordance with ASHRAE standard 193
• Cabinet air leakage less than 1.4% at 0.5 inch H₂O when tested in accordance with ASHRAE standard 193
• AHRI certified; ETL listed
• Rigid SmartFrame™ cabinet
• Horizontal or vertical configuration capabilities
• 21″ depth for easier attic access
• DecaBDE-free thermoplastic drain pan with secondary drain connections
• Screw-less sides and back helps to reduce condensation when installed in humid locations
• Foil-faced insulation covers the internal casing to reduce cabinet condensation
• Galvanized, leather grain-embossed finish
• Glue-less cabinet insulation retention
• Tool-less filter access
• Field Installed 3 kW – 25 kW electric heater kits available
ARUF37C14 | |
Nominal Ratings | |
Cooling (Btu/h) | 36,000 |
Piston Size | 0.072 |
Blower | |
Diameter | 10⅝” |
Width | 8″ |
Coil Connections | |
Liquid | ⅜” |
Suction | ⅞” |
Coil Drain Connect (FPT) | ¾” |
Electrical Data | |
Voltage | 208/230 |
Min Circuit Ampacity | 4/4 |
Max. Overcurrent Device (Amps) | 15/15 |
Minimum VAC | 197 |
Maximum VAC | 253 |
Blower Motor | |
Full Load Amps (FLA) | 3.0 |
Horsepower (HP) | ⅓ |
Ship Weight (Lbs.) | 130 |