Standard Features
• Energy-Efficient Compressor
• Copper tube/ enhanced aluminum fin coil-5mm diameter on 1.5-4.0T
• Factory-installed filter drier
• Fully charged for 15’ of tubing length
• Service valves with sweat connections and easy-to-access gauge ports
• Contactor with lug connection
• Ground lug connection
• AHRI Certified
• ETL Listed
Cabinet Features
• Removable grille-style top design compliant with UL 60335-2-40
• Heavy-gauge galvanized-steel cabinet
• Attractive Architectural Gray powder-paint finish with 500-hour salt-spray approval
• Steel louver coil guard
• Single-panel access to controls with space provided for field-installed accessories
• When properly anchored, meets the 2020 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)
Standard Features
• Heavy-duty aluminized-steel dual- diameter tubular heat exchanger
• Single-stage gas valve
• Durable Hot-surface igniter
• Quiet, single-speed draft induced
• Self-diagnostic control board
• Color-coded low-voltage terminals
• Multi-speed ECM blower motor
• California Low NOx emissions models available
• Can no longer be installed in California’s South Coast Air Quality Management District (SCAQMD) on or after October 1, 2019.
• AHRI Certified; ETL Listed
Cabinet Features
• Installation:
– GM9S80-upflow, horizontal left or right
– GC9S80- downflow, horizontal left or right
• Convenient left or right connection for gas and electrical service
• Heavy-gauge steel cabinet with durable baked-enamel finish
• Foil faced insulated heat exchanger
Standard Features
• All-Aluminum evaporator coil
• Optimized for use with R-410A refrigerant
• Some models suitable for use with R-410A or R-22 refrigerant
• CAPT, CAPTA, CHPT, CHPTA models feature factory-installed thermal expansion valves for cooling and heat pump applications
• CAPF, CAPFA, CAUF, CAUFA, CHPF, CSCF models feature a check flowrator for cooling and heat pump applications
• Vertical and horizontal models available
• 21” depth for easier attic access
• Foil-faced insulation covers the internal casing to reduce cabinet condensation
• Galvanized, leather grain-embossed finish
• Rust resistant, thermoplastic drain pans featuring a low water-retention design
• DecaBDE-free thermoplastic drain pan with secondary drain connections
• UV-resistant drain pan
• AHRI certified; ETL listed
California Residents- Proposition 65
GM9S800603BN | GSXN403610 | CHPTA3630B4 | |||||
Heating Capacity | Capacities | Unit Dimensions | |||||
Input | 60,000 | Nominal Cooling (BTU/h) | 36,000 | W | 30″ | ||
Natural Gas Output | 48,000 | Decibels (dBA) | 72 | D | 21″ | ||
LP Gas Output | 48,000 | Compressor | H | 17½” | |||
AFUE ¹ | 80 | RLA | 16 | Nominal Tons | 3 | ||
Available AC @ 0.5” ESP | 3 | LRA | 91.9 | ||||
Temperature Rise Range (°F) | 20-50 | Stage | Single | Connection | |||
Circulator Blower | Type | Scroll | Liquid | ⅜” | |||
Size (D x W) | 10″ x 8″ | Condenser Fan Motor | Suction | ⅞” | |||
Horsepower @1075 RPM | 0.5 | Motor Type | PSC | Ship Weight (lbs) | 66 | ||
Speed | 9 | Horsepower | ⅙ | ||||
Vent Diameter ² | 4″ | FLA | 0.95 | ||||
No. of Burners | 3 | Refrigeration System | |||||
Electrical Data | Refrigerant Line Size | ||||||
Min. Circuit Ampacity | 8.7 | Liquid Line Size (“O.D.) | ⅜” | ||||
Max. Overcurrent Device (amps) | 15 | Suction Line Size (“O.D.) | ⅞” | ||||
Ship Weight (lbs) | 100 | Refrigerant Connection Size | |||||
Liquid Valve Size (“O.D.) | ⅜” | ||||||
Suction Valve Size (“O.D.) | ⅞” | ||||||
Valve Type | Sweat | ||||||
Refrigerant Charge | 95 | ||||||
Electrical Data | |||||||
Voltage-Phase (60 Hz) | 208/230-1 | ||||||
Minimum Circuit Ampacity | 21 | ||||||
Max. Overcurrent Protection | 35 | ||||||
Min / Max Volts | 197/253 | ||||||
Electrical Conduit Size | ½” or ¾” | ||||||
Equipment Weight (lbs) | 188 | ||||||
Ship Weight (lbs) | 210 |