(This Product Is Discontinued)
This system is being phased out. Follow the link below to the new SEER2 model.
3.5 Ton 14.5 SEER2 Goodman Heat Pump Split System GSZB404210+AMST42CU1400 (ushvacwarehouse.com)
Install Kit Includes:
* 50′ Copper Insulated Line Set
* Drain Float Switch
* 6′ Electrical Whip
* 60 amp non fused disconnect
* Plastic Condenser Pad
* Digital Thermostat
* Heat Strip up to 10 kw
Standard Features
• Energy-efficient compressor
• Single-speed condenser fan motor
• Factory-installed filter drier
• Copper tube/aluminum fin coil
• Service valves with sweat connections and easy-access gauge ports
• Contactor with lug connection
• Ground lug connection
• AHRI Certified; ETL Listed
Cabinet Features
• Heavy-gauge galvanized-steel cabinet with a louvered sound control top
• Attractive Architectural Gray powder-paint finish with 500-hour salt-spray approval
• Steel louver coil guard
• Top and side maintenance access
• Single-panel access to controls with space provided for field-installed accessories
• When properly anchored, meets the 2010 Florida Building Code unit integrity requirements for hurricane- type winds (Anchor bracket kits available.)
Nominal Capacities | GSZ140421 |
Cooling (BTU/h) | 42,000 |
Heating (BTU/h) | 42,000 |
Decibels | 75 |
Compressor | |
RLA | 16.7 |
LRA | 109.0 |
Type | Scroll |
Condenser Fan Motor | |
Horsepower | 1/6 |
FLA | 1.1 |
Refrigeration System | |
Refrigerant Line Size¹ Liquid Line Size (“O.D.) | ⅜” |
Suction Line Size (“O.D.) | 1⅛” |
Refrigerant Connection Size | |
Liquid Valve Size (“O.D.) | ⅜” |
Suction Valve Size (“O.D.) | ⅞” |
Standard Line Set Length (max. feet) | 80 |
Long Line Set Length (max. feet) ² Equivalent Length | 250 |
Linear Length | 200 |
Vertical Length (outdoor below indoor) | 80 |
Vertical Length (outdoor above indoor) | 80 |
Valve Connection Type | Sweat |
Refrigerant Charge | 153 |
Electrical Data | |
Volts/Phase (60 Hz) | 208-230/1 |
Minimum Circuit Ampacity ³ | 22.0 |
Max. Overcurrent Protection ⁴ | 35 |
Min / Max Volts | 197 / 253 |
Electrical Conduit Size | ½” or ¾” |
Unit Weights | |
Equipment Weight (lbs.) | 191 |
Ship Weight (lbs) | 207 |
ENERGY STAR® Certified ^ |
Product Features
-Internal factory-installed thermal expansion valves for cooling and heat pump applications
-Direct drive, multi-speed ECM blower motor
-All-aluminum evaporator coil
-Coil mounting track for quick repositioning
-Optimized for use with R-410A refrigerant
-Cabinet air leakage less than 2.0% at 1.0 inch H₂O when tested in accordance with ASHRAE standard 193
-AHRI certified; ETL listed
-Tool-less filter access
-Field Installed 3 kW – 25 kW electric heater kits available
-Rigid SmartFrame™ cabinet
-Horizontal or vertical configuration capabilities
– 21” depth for easier attic access
-DecaBDE-free thermoplastic drain pan with secondary drain connections
– Screw-less sides and back helps to reduce condensation when installed in humid locations
-Foil-faced insulation covers the internal casing to reduce cabinet condensation
– Galvanized, leather grain-embossed finish
-Glue-less cabinet insulation retention
ASPT47C14 | |
Nominal Ratings | 42,000 |
Cooling (Btu/h) | |
Blower | |
Diameter | 10⅝” |
Width | 10⅝” |
Coil Connections | |
Liquid | ⅜” |
Suction | ⅞” |
Coil Drain Connect (FPT) | ¾” |
Electrical Data | |
Voltage | 208/230 |
Minimum Circuit Ampacity | 4.9 / 4.9 |
Max. Overcurrent Device (Amps) | 15 / 15 |
Minimum VAC | 197 |
Maximum VAC | 253 |
Blower Motor | |
Full Load Amps (FLA) | 3.9 |
Horsepower (HP) | ¾ |
Ship Weight (Lbs.) | 144 |