(This Product Is Discontinued)
2 Ton 14 SEER Goodman HEAT PUMP Split GSZ140241 & ARUF25B14 R410a INSTALL KIT
Install Kit Includes:
* 30′ Copper Insulated Line Set
* Drain Float Switch
* 6′ Electrical Whip
* 60 amp non fused disconnect
* Plastic Condenser Pad
* Digital Thermostat
* Heat Strip up to 10 kw
Standard Features Cabinet Features
• High-efficiency scroll compressor
• SmartShift® technology to ensure quiet reliable defrost
• Factory-installed bi-flow liquid-line filter drier
• Factory-installed suction-line accumulator
• Factory-installed compressor crankcase heater
• Factory-installed high-capacity muffler
• High- and low-pressure switches
• Service valves with sweat connections
and easy access to gauge ports
• Copper tube/enhanced aluminum fin coil
• Fully charged for 15’ of tubing length
• Contactor with lug connection
• Ground lug connection
• AHRI Certified; ETL Listed
Cabinet Features
• Goodman® brand sound control top design
• Steel louver coil guard
• Heavy-gauge galvanized-steel cabinet
• Attractive Architectural Gray powder-paint finish with 500-hour salt-spray approval
• Top and side maintenance access
• Service ports and controls are
accessible while unit is operating
• When properly anchored, meets the 2010 Florida Building Code unit integrity requirements for
hurricane-type winds (Anchor bracket kits available.)
GSZ140241 | |
Nominal Capacities | |
Cooling (BTU/h) | 24,000 |
Heating (BTU/h) | 24,000 |
Decibels | 72 |
Compressor | |
RLA | 10.9 |
LRA | 62.9 |
Type | Scroll |
Condenser Fan Motor | |
Horsepower | 1/6 |
FLA | 0.95 |
Refrigeration System | |
Refrigerant Line Size¹ | |
Liquid Line Size (“O.D.) | ⅜" |
Suction Line Size (“O.D.) | ¾" |
Refrigerant Connection Size | |
Liquid Valve Size (“O.D.) | ⅜" |
Suction Valve Size (“O.D.) | ¾" |
Standard Line Set Length (max. feet) | 80 |
Long Line Set Length (max. feet) ² | |
Equivalent Length | 250 |
Linear Length | 200 |
Vertical Length (outdoor below indoor) | 80 |
Vertical Length (outdoor above indoor) | 80 |
Valve Connection Type | Sweat |
Refrigerant Charge (oz.) | 108 |
Electrical Data | |
Volts/Phase (60 Hz) | 208-230/1 |
Minimum Circuit Ampacity ³ | 14.6 |
Max. Overcurrent Protection ⁴ | 25 |
Min / Max Volts | 197 / 253 |
Electrical Conduit Size | ½" or ¾" |
Unit Weights | |
Equipment Weight (lbs.) | 143 |
Ship Weight (lbs) | 154 |
ENERGY STAR® Certified ^ | YES |
Product Features
• Check flowrator for cooling and heat pump applications
• Direct drive, multi-speed PSC blower motor
• All-aluminum evaporator coil
• Coil mounting track for quick repositioning
• Cabinet air leakage less than 2.0% at 1.0 inch H₂O when tested in accordance with ASHRAE standard 193
• Cabinet air leakage less than 1.4% at 0.5 inch H₂O when tested in accordance with ASHRAE standard 193
• AHRI certified; ETL listed
• Rigid SmartFrame™ cabinet
• Horizontal or vertical configuration capabilities
• 21″ depth for easier attic access
• DecaBDE-free thermoplastic drain pan with secondary drain connections
• Screw-less sides and back helps to reduce condensation when installed in humid locations
• Foil-faced insulation covers the internal casing to reduce cabinet condensation
• Galvanized, leather grain-embossed finish
• Glue-less cabinet insulation retention
• Tool-less filter access
• Field Installed 3 kW – 25 kW electric heater kits available
ARUF25B14 | |
Nominal Ratings | |
Cooling (Btu/h) | 24,000 |
Piston Size | 0.051 |
Blower | |
Diameter | 9½" |
Width | 6" |
Coil Connections | |
Liquid | ⅜" |
Suction | ¾" |
Coil Drain Connect (FPT) | ¾" |
Electrical Data | |
Voltage | 208/230 |
Min Circuit Ampacity | 2.2/2.2 |
Max. Overcurrent Device (Amps) | 15/15 |
Minimum VAC | 197 |
Maximum VAC | 253 |
Blower Motor | |
Full Load Amps (FLA) | 1.75 |
Horsepower (HP) | ⅓ |
Ship Weight (Lbs.) | 100 |
Product Documents