(This Product Is Discontinued)
This system is being phased out. Follow the link below to the new SEER2 model.
Install Kit Includes:
* 50′ Copper Insulated Line Set
* Drain Float Switch
* 6′ Electrical Whip
* 60 amp non fused disconnect
* Plastic Condenser Pad
* Digital Thermostat
* Heat Strip up to 10 kw
Standard Features
- Energy-efficient compressor
- Single-speed condenser fan motor
- Factory-installed filter drier
- Copper tube/aluminum fin coil
- Service valves with sweat connections and easy-access gauge ports
- Contactor with lug connection
- Ground lug connection
- AHRI Certified; ETL Listed
Cabinet Features
- Heavy-gauge galvanized-steel cabinet with a louvered sound control top
- Attractive Architectural Gray powder-paint finish with 500-hour salt-spray approval
- Steel louver coil guard
- Top and side maintenance access
- Single-panel access to controls with space provided for field-installed accessories
- When properly anchored, meets the 2010 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)
GSX140241 | |
Capacities | |
Max Cooling (BTU/h) | 24,000 |
SEER/EER | 14 / 12 |
Decibels | 74 |
Compressor | |
RLA | 7.7 |
LRA | 38.0 |
Condenser Fan Motor | |
Hp | 1/8 |
FLA | 0.7 |
Refrigeration System Refrigerant Line Size ¹ | |
Liquid Line Size (“O.D.) | ⅜” |
Suction Line Size (“O.D.) | ¾” |
Refrigerant Connection Size | |
Liquid Valve Size (“O.D.) | ⅜” |
Suction Valve Size (“O.D.) ² ³ | ¾” |
Valve Type | Sweat |
Charge | 72 |
Included piston: | 0.057 |
Electrical Data | |
Voltage-Phase (60 Hz) | 208/230-1 |
Minimum Circuit Ampacity ⁴ | 10.3 |
Max. Overcurrent Protection ⁵ | 15 amps |
Min/Max Volts | 197/253 |
Conduit | ½” or ¾” |
Product Features
-Check flowrator for cooling and heat pump applications
-Direct drive, multi-speed PSC blower motor
-All-aluminum evaporator coil
-Coil mounting track for quick repositioning
-Cabinet air leakage less than 2.0% at 1.0 inch H₂O when tested in accordance with ASHRAE standard 193
-Cabinet air leakage less than 1.4% at 0.5 inch H₂O when tested in accordance with ASHRAE standard 193
-AHRI certified; ETL listed
-Tool-less filter access
-Field Installed 3 kW – 25 kW electric heater kits available
-Rigid SmartFrame™ cabinet
-Horizontal or vertical configuration capabilities
-21″ depth for easier attic access
-DecaBDE-free thermoplastic drain pan with secondary drain connections
-Screw-less sides and back helps to reduce condensation when installed in humid locations
-Foil-faced insulation covers the internal
casing to reduce cabinet condensation
-Galvanized, leather grain-embossed finish
-Glue-less cabinet insulation retention
ARUF29B14 | |
Nominal Ratings | |
Cooling (Btu/h) | 25,000 |
Piston Size | 0.057 |
Blower | |
Diameter | 9½” |
Width | 6″ |
Coil Connections | |
Liquid | ⅜” |
Suction | ¾” |
Coil Drain Connect (FPT) | ¾” |
Electrical Data | |
Voltage | 208/230 |
Min Circuit Ampacity | 2.2/2.2 |
Max. Overcurrent Device (Amps) | 15/15 |
Minimum VAC | 197 |
Maximum VAC | 253 |
Blower Motor | |
Full Load Amps (FLA) | 1.75 |
Horsepower (HP) | ⅓ |
Ship Weight (Lbs.) | 100 |
$2,673.00
-