- Neodymium magnets are used in the pink-coloured area.
- 1. A neodymium magnet is approximately 10 times stronger than a standard ferrite magnet.
- Swing Compressor- Thanks to its smooth rotation, the swing compressor decreases friction and vibration. It also prevents the leakage of refrigerant gas during compression. These advantages provide quiet and efficient operation.
- DC Inverter- DC Inverter models are equipped with the Reluctance DC motor for compressors. The Reluctance DC motor uses 2 different types of torque, neodymium magnet¹ and reluctance torque².This motor saves energy by generating more power with a smaller electric current than AC or conventional DC motors. It is more efficient at the low frequencies most commonly used by air conditioners³
- 2. The torque created by the change in power between the iron and magnet parts.
3. The frequency range used by air conditioners during periods of stable operation.
This is the range in which air conditioners operate for the longest periods - Advantages of Inverter technology
- Superior comfort
- Higher efficiency
- Powerful operation
- Better energy savings
- Fixed speed (non-inverter) systems operate by compressor start-stop cycles which consumes more energy and have higher variance of the room temperature.
- Flexible performance, rapid response time
- After quickly reaching set temperature, the inverter system constantly adjusts and fine-tunes the cooling capacity to prevent undesired temperature swings. Room comfort level is constantly maintained even when the number of people in the room increases or decreases.
-
-
- Powerful operation- Once activated, this feature will engage the indoor fan motor to run at maximum speed for 20 minutes. The turbo airflow enables the desired temperature to be achieved faster, especially in larger spaces.
- ECO+- An intelligent feature that ensures optimum energy consumption while fulfilling basic human comfort needs. Once activated, set temperature will be adjusted automatically to an eco-friendly level while limiting the maximum power consumption.
- Sleep mode- Pressing the Sleep button activates the Sleep Mode. This function prevents excessive cooling/heating for a pleasant sleep.
- Catechin Filter- This filter is infused with catechin extracted from green tea. This substance deactivate bacteria and virus captured on the filter surface. On top of that, this substance stop any mildew grow on the filter surface.
- Titanium Apatite Deodorizing Filter- Titanium apatite filter is a filter with advanced adsorption power and effectively deodorizing odours. The filter delivers consistent performance for approximately 3 years if washing with water is performed once every 6 months.
-
RXNG18AXVJU FTXNG18AXVJU
Class | 18 | |||
Model Name | Indoor | FTXNG18AXVJU | ||
Outdoor | RXNG18AXVJU | |||
Rated Cooling Capacity (Min ~ Max) | Btu/hr | 18,000 (6,700 – 20,000) | ||
kW | 5.27 (1.96 – 5.86) | |||
Rated Heating Capacity (Min ~ Max) | Btu/hr | 17,900 (5,800 – 22,500) | ||
kW | 5.24 (1.70 – 6.60) | |||
Btu/hr | Cooling | W | 1714 | |
Heating | W | 1590 | ||
Rated EER2 | Btu/hr/W | 10.5 | ||
W/W | 3.08 | |||
Rated COP | Btu/hr/W | 11.26 | ||
W/W | 3.30 | |||
SEER | 18.0 | |||
HSPF | 8.5 | |||
Power Supply | (V/pH/Hz) | 208/230/1/60 | ||
Power Supply | ft (m) | 98-1/2 (30) | ||
Maximum Piping Length | ft (m) | 32-13/16 (10) | ||
Maximum Piping Elevation | ft (m) | 32-13/16 (10) | ||
Piping Connections | Liquid | inch (mm) | 1/4 (6.4) | |
Gas | inch (mm) | 1/2 (12.7) | ||
Operating range – Cooling | ˚F (˚C) | 50 – 114.8 (10 – 46) | ||
Operating range – Heating | ˚F (˚C) | 5 – 64.4 (-15 – 18) | ||
Operating range – Ambient Cooling | ˚F (˚C) | 5 – 114.8 (-15 – 46) | ||
Indoor Unit | ||||
Unit Dimension | H | inch (mm) | 11-11/16 (297) | |
W | inch (mm) | 39-9/16 (990) | ||
D | inch (mm) | 10-3/4 (273) | ||
Sound Pressure Level (T/H/M/L/SL) | Cooling | dBA | 50/48/43/37/33 | |
Heating | 49/46/41/36/33 | |||
Airflow (T/H/M/L/SL) | Cooling | CFM | 754/716/605/467/395 | |
Heating | 754/716/605/467/395 | |||
Unit weight | lbs (kg) | 31 (14) | ||
Outdoor Unit | ||||
Unit Dimension | H | inch (mm) | 27-13/32 (696) | |
W | inch (mm) | 36-5/8 (930) | ||
D | inch (mm) | 13-13/16 (351) | ||
Sound Pressure Level (H) | Cooling | dBA | 53 | |
Heating | 53 | |||
Unit weight | lbs (kg) | 97 (44) |